Balboa ML260 Uživatelský manuál Strana 8

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 18
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 7
Page 8 55494_97_A
Program Filter Cycles by Duration n Y
n = Start and stop times; for time capable panels.
Y = Duration; for non-time capable panels = 1 DIP Switch
Pump 1 in Filter (w/Circ Pump) n Y (This feature is used in Circ Mode only.)
Allows Pump 1 Low to operate in Filter Cycles to add extra filtration.
n = Normal; Y = Pump 1 with Circ
24-Hour Time * n Y
n = 12-hour (am/pm); Y = 24-hour (military\European); =
1 DIP Switch
* Sets default for user preferences - only applies when persistent memory is reset (A12 On) during power-up.
Celsius * n Y
n = Fahrenheit; Y = Celsius; = 1 DIP Switch
* Sets default for user preferences - only applies when persistent memory is reset (A12 On) during power-up
Timeouts 1 F 2 3 4 5 6
1-6 = 10, 20, 30, 40, 50, 60 minutes; F = 15 minutes
Pump 1 Low Timeout d 1 2 3 4
d = Use “Timeouts” value above; 1-4 = number of hours; =
3 DIP Switch
Light Timeout d 1 2 3 4
d = Use “Timeouts” value above; 1-4 = number of hours
Scrunch Panel n Y
n = Normal panel layout;
Y = Alternate panel layout (ML900 scrunching enabled - ML550/700
Jets 3 replaces Blower; = 1 DIP Switch
Circ Type (behavior) n A 3 P
n = Non circ or circ pump not plumbed with heater; A = 24-hour;
3 = 24-hour with 3ºF shutoff outside filter;
P = Acts like Pump 1 Low (filter cycles, polls, etc.); = 2 DIP Switch
Pump 1 Speeds 1 2
1 = 1 speed; 2 = 2 speed; = 1 DIP Switch
Pump 2 Speeds 0 1 2
0 = Disabled; 1 = On/Off; 2 = 2 speed; = 2 DIP Switch
Pump 3 Speeds 0 1 2
0 = Disabled; 1 = On/Off; 2 = 2 speed; = 3 DIP Switch
Pump 4 Speeds 0 1 E H L
0 = Disabled; 1 = On/Off on board; E = External X-P CE or X-P231 CE Relay;
H = On/Off on pin 1 of X-P632 CE board; L = 2 speed on X-P632 CE board; = 3 DIP Switch
Pump 5 Speeds 0 1 E L
0 = Disabled; 1 = On/Off on board; E = External X-P CE or X-P231 CE Relay;
L = On/Off on pin 2 of X-P632 CE board; = 3 DIP Switch
Software Configuration Settings
PUMP SPEEDS
Default
As Set
As Set to Default